Aquamax KF Plus
Reliable Water Content Determination

Product description
The Aquamax KF Plus series is designed for accurate water content determination according to international standards (ASTM, API, BS, DIN, EI/IP, EN, IEC, ISO), combining the Karl Fischer method with precise coulometry.
Compact, robust, and user-friendly, the Aquamax KF Plus and Aquamax KF Portable titrators feature a tough measuring vessel, intuitive ‘press-go’ operation, and a built-in printer for immediate documentation.
Thanks to their small footprint and fully enclosed components, these instruments save valuable lab space and are easy to transport.
The integrated battery ensures flexible operation outside the lab — ideal for mobile labs, fieldwork, or unstable power environments.
Key Features:
- Water determination according to international standards
- Tough and durable measuring system
- Compact design with enclosed parts for portability
- Built-in battery for mobile or remote use
- Easy operation with a press-go keypad and integrated printer

Aquamax KF PLUS

Standard Conformity
The Aquamax KF Series coulometric Karl Fischer Titrators can be used for the following standard methods:
ASTM D 1364, ASTM D 1533, ASTM D 3401, ASTM D 4928, ASTM 6304, ASTM D 7995, API Ch. 10.9, BS 6829:1.5, DIN 51777, DIN EN 60814, DIN EN ISO 12937, EI / IP 386, EI /IP 438, ISO TC158/SC, ISO 10101-1, ISO 10101-3, ISO 10337

Features and Results
- Simple operation
- 10 user programmable methods
- 1 ppm/100 %
- Results in ppm, mg/kg, % water, µg water
- Multi language display & printout
- Small footprint
- Integral high speed printer
- Integral battery
- Fully portable
- Low drift cell design
- Automatically compensated errors (patented technique)
- Operable without additional PC

Gas tight sampling syringes
Each Aquamax KF Plus/Portable is supplied with a white lettered gas tight sampling syringe and luer needle which has been designed specifically for accurate sampling of oils and fuels.

Water check
The µg check button allows the operator to simply press go, inject 1 µL or maybe 10 µL of distilled water (as required by some ASTM methods) and verify if the instrument and reagent are working with in their required specification.
The µg check overrides the programmed calculation and displays/prints out a report of the verification check.
The coulometer then automatically reverts to the pre-programmed setting.

Aquamax KF PLUS water check

Tough measuring vessel
The unique LDC glassware design is by far the easiest to use and the most robust. The electrode locking system allows the joints to seal completely, without the use of grease or PTFE sleeves, and provides improved baseline stability. Hassle free assembly and disassembly.

Aquamax KF PLUS measuring vessel

Where do you need an Aquamax KF
From raw materials to finished products, to preventive maintenance programs, you will find Aquamax KF in the labs, the back of mobile rigs and even on-line as part of an industrial process. If you are testing any of the following processes and samples you may need an Aquamax KF instrument to test you water content!
- Exploration and Production of Crude Oil and Natural Gases
- Refining of petroleum products like Bitumen, Fuel Oil, Lubricating Oils, Waxes, Polishes, Diesel Fuel, Jet Fuel, Paraffin, Petrochemicals, Gasoline and Bottled Gas (LPG)
- Pipeline & Transportation of oils, fuels and petrochemicals
- Biofuels
- Plastic & polymer components
- Pharmaceutical products
- Extracts like cannabis oil and vaping fluids

Aquamax KF PLUS measuring vessel

Technical specifications
Device Type | Main unit |
Power supply | 230 V/50 Hz or 110 V/60 Hz |
Dimensions (L x H x D) | 290 x 255 x 130 mm |
Internal power supply | 18 V/DC |
Power input | 40 W |
Weight | 3 kg |
Titration method | Coulometric Karl Fischer titration |
Electrolysis control | Patented “ACE” control system Gb2370641 |
End point detection | AC polarisation |
End point indication | Visual display/print out/acoustic beep |
Titration vessel | Low Drift Cell design,
no grease or PTFE sleeves required |
Measuring range | Possible 1 µg - 200 mg water
Typical 1 µg - 10 mg water |
Water content | 1 ppm - 100 % water |
Max. sensitivity | 0.1 µg |
Max. titration speed | 2 mg per minute |
Max. current | 350 mA |
Drift compensation | Automatically controlled |
Precision | 10 - 100 µg ± 3 µg; 100 µg - 1 mg ± 3 µg,
above 1 mg ± 0.3 % |
Start delay time | 0 - 30 minutes, user selectable |
End delay time | 0 - 30 minutes, user selectable |
Calculation modes | Weight/weight (W/w) (user programmable), Weight/dilution ratio (W/K) Volume/density (V/SG) Volume/volume (V/v) |
Display format | µg, mg/kg, ppm, % |
Print format | µg, mg/kg, ppm, % |
Statistics | max, mean, min values up to 99 runs |
Method storage | 10 user programmable methods |
Sample ID number | User programmable |
Stirrer speed | Microprocessor controlled |
Languages | Multi languages |
Calendar/clock | Analysis time & date print out |
Battery low indicator | Display & print out indication |
Removable data storage | Flash drive (memory stick) - optional |
Data entry | 15 key touchpad |
Display | 40 character alphanumeric backlight LCD |
Printer | 42 character high speed thermal